Product
News 2004
BURLE
Electro-Optics Announces Enhanced 40mm Diameter
Time-of-Flight Detector for Mass Spectrometry Applications
BURLE
Electro-Optics Announces 40 mm Diameter BiPolar Time-of-Flight
Detector for Mass Spectrometry Applications
New
Bench-Top Power Supply for MCP Based Photomultipliers Now In-Stock
Electronic
Imaging Detector System Provides Visual Images
of Charged Particles and Ultraviolet Radiation
New
Miniature Time-of-Flight Detectors Meet the Continuing Needs of
Homeland Security.
BURLE
Industries to Introduce New Photosensor Modules at Pittcon 2004.
top
BURLE
Electro-Optics Announces Enhanced 40mm Diameter
Time-of-Flight Detector for Mass Spectrometry Applications
Sturbridge, MA –
October 11, 2004 – BURLE Electro-Optics, Inc. announces
the offering of its enhanced performance 40mm diameter Time-of-Flight
Detector. The new patented detector’s small pore 5-micron
Extended Dynamic Range™ MCP technology and large collection
area (12.5 cm2) is unique in the market and offers higher performance,
improved mass resolution and fast timing for TOF Mass Spectrometry.
The detector’s
large format and 760 ps pulse width offers previously unobtainable
levels of mass resolution, dynamic range, and detection sensitivity
that is ten times that of conventional MCPs. The new detector
is housed in BURLE’s Quick-Fit® replaceable MCP cartridge
to make maintenance fast and easy. The cartridges include a set
of two Chevron™ Long-Life™ small pore MCPs and a high
voltage transmission grid mounted in a rugged module with an integral
50 Ohm impedance matched conical anode. This module is available
separately or mounted on a 6” Conflat flange.
The addition
of BURLE Electro-Optics’ 40mm Time-of-Flight Detector rounds
out the largest selection available anywhere with over 20 models
from 8mm to 40mm sizes.
BURLE Electro-Optics,
Inc., headquartered in Sturbridge, Massachusetts, is the world
leader in Time-of-Flight detector technology and offers the highest
temporal resolution detectors for both ADC and TDC based systems.
A pioneer in developing scientific detector products, the company
is recognized as the worldwide leader in electron multiplication
technology for its Channeltron® Mass Spectrometer Detectors,
Long-Life™ Microchannel Plates and Advanced Performance
Detectors.
top
BURLE
Electro-Optics Announces 40 mm Diameter BiPolar Time-of-Flight
Detector for Mass Spectrometry Applications
Sturbridge,
MA – August 20, 2004 – BURLE Electro-Optics, Inc.
announces its new patented high performance, high speed BiPolar
Time-of-Flight detector for Mass Spectrometry applications. This
detector offers levels of sensitivity, temporal resolution, dynamic
range, and high mass detection currently not available in the
market. In addition to its large 40 mm diameter (12.5 cm2) detection
area and up to 10 kV post acceleration, it offers BURLE’s
exclusive Extended Dynamic Range™ small pore Microchannel
Plates (MCPs) with high channel densities.
The new detector is enclosed in a low-profile assembly combining
a highly sensitive Microchannel Plate and electro-optically isolated
output signal. It is available separately for flight tube mounting,
unmounted, or on a conflat flange.
A unique feature
of the new detector is its flat MCP input surface. It can be biased
up to ±10 kV to enhance detection of high mass, positive
or negative ions. In addition, a proprietary enhancement coating
is added to the ion conversion surface for greater conversion
efficiency. The detector offers system gains up to 107 and excellent
temporal bi-polar resolution.
BURLE’s Quick-Fit® replaceable MCP cartridge makes maintenance
easy and fast. These cartridges include a Long-Life™ MCP
and a high voltage transmission grid mounted in a rugged module.
The module can be replaced easily and quickly with minimum downtime.
The addition
of BURLE Electro-Optics’ patented 40 mm BiPolar Time-of-Flight
Detector rounds out the largest selection of Time-of-Flight detectors
available in the world with 18 models in sizes ranging from 8
mm to 40 mm.
BURLE Electro-Optics, Inc., headquartered in Sturbridge, Massachusetts,
is the world leader in Time-of-Flight detector technology and
offers the highest temporal resolution detectors for both ADC
and TDC based systems. A pioneer in developing scientific detector
products, the company is recognized as the worldwide leader in
electron multiplication technology for its Channeltron® Mass
Spectrometer Detectors, Long-Life™ Microchannel Plates and
Advanced Performance Detectors.
For general information, specifications, samples and pricing please
contact BURLE Electro-Optics
at 1-800-648-1800 or 1-508-347-4000 email: sales@burle-eo.com.
top
New
Bench-Top Power Supply for MCP Based Photomultipliers Now In-Stock
Lancaster, PA – April 5, 2004 – BURLE INDUSTRIES,
INC. announces its newest high voltage power supply designed
for MCP based photomultipliers is now in-stock and ready
for online ordering or though BURLE Customer Service. The
PF1056 is a high precision analog programmable power supply
ideally suited for laboratory or test environments. It provides
output up to -5000 V at 667 µa. while offering excellent
stability and low ripple suitable for the most demanding
MCP-PMT applications.
The PF1056 offers excellent
stability and low ripple suitable for the most demanding
MCP-PMT applications. With its analog I/O, it lends itself
to automated test and calibration type applications. Its
built-in safeguards protect sensors against repetitive discharge
events by shutting down and presenting a logic level indicating
the event.
The
PF1056 offers both precision and performance in a compact
unit providing clean repeatable output voltage monitored
clearly on the front panel. Technical specifications include
ripple <15 mV, line and load regulation <0.01%, drift <0.02%/day
and a temperature coefficient of ±100 ppm/°C.
Other important features incorporated
into the unit include disabling output remotely so that it
may be interlocked to a user process. CE Certification is
pending.
For
additional product and ordering information concerning the
PF1056 Power Supply contact BURLE INDUSTRIES, INC. 1000 New
Holland Avenue, Lancaster, PA 17601-5688 USA; 800-366-2875,
717-295-6888, International Calls: 717-295-6773, Fax: 717-295-6096,
E-Mail: burlesls@burle.com; web site: www.burle.com
top
Electronic
Imaging Detector System Provides Visual Images
of Charged Particles and Ultraviolet Radiation
Sturbridge,
MA – February 11, 2004 – BURLE Electro-Optics, Inc.
announces the development and offering of a new detector system
that allows experimenters and designers to determine the location,
shape, and size of a charged particle or UV beam. It is ideal
for ion beam profiling in instrument design or high-energy physics
experiments and verifying ion optic models.
BURLE’s
new Electronic Imaging Detector System consists of a 25mm active
diameter Microchannel plate detector mounted on a conflat flange.
The Microchannel plates (MCPs) detects and amplify ion or photon
events by producing a shower of electrons in the position of the
input event. The resultant shower of electrons is converted to
an optical image by a fiber optic phosphor screen. This image
is then captured by an integral CCD camera and then sent to a
frame grabber allowing the user to manipulate and archive frames
to their PC.
The entire
system includes the detector assembly with the CCD camera already
mounted, the frame grabber board (for installation into your PC)
and software.
BURLE Electro-Optics,
Inc., headquartered in Sturbridge, Massachusetts, is the world
leader in Time-of-Flight detector technology, offering the highest
temporal resolution detectors for both ADC and TDC based systems.
A pioneer in developing scientific detector products, the company
is recognized as the worldwide leader in electron multiplication
technology for its Channeltron?® Mass Spectrometer Detectors,
Long-Life™ Microchannel Plates and Advanced Performance
Detectors.
For general
information, specifications and pricing for the Electronic Imaging
Detector, please contact BURLE Electro-Optics, Inc. at 1-800-648-1800
or 1-508-347-4000 email: sales@burle-eo.com.
top
New
Miniature Time-of-Flight Detectors Meet the Continuing Needs of
Homeland Security.
Sturbridge,
MA – March 1, 2004 – BURLE Electro-Optics, Inc. introduces
its new line of Miniature Advanced Performance, Time-of-Flight
Detectors. They are the ideal solution for small, portable Mass
Spectrometry detection devices especially those intended for homeland
security applications.
These new
miniature detectors offer a range of configurations and previously
unobtainable levels of mass resolution, dynamic range, and detection
sensitivity. The high performance detectors are offered in the
most compact packages available to help make portable instruments
smaller and lighter. Their unique size offers an 8mm flat input
surface providing uniform ion conversion gains in excess of 106.
It may be operated at up to 100°C and vacuum baked at up to
150°C allowing rapid chamber degassing and ultra quiet instrument
operation.
Each Detector
utilizes two 5-micron Long-Life™, small pore, Extended Dynamic
Range™ microchannel plates (arranged as a Chevron™.) mounted on
a compact vacuum flange for easy installation.
BURLE Electro-Optics,
Inc., headquartered in Sturbridge, Massachusetts, is the world
leader in Time-of-Flight detector technology, offering the highest
temporal resolution detectors ranging in size from 8mm to 40mm
diameters for both ADC and TDC based systems. A pioneer in developing
scientific detector products, the company is recognized as the
worldwide leader in electron multiplication technology for its
Channeltron® Mass Spectrometer Detectors, Long-Life™
Microchannel Plates and Advanced Performance Detectors.
For general
information, specifications and pricing for the miniature TOF
detector, please view
this data sheet or contact BURLE Electro-Optics, Inc. at 1-800-648-1800
or 1-508-347-4000 email: sales@burle-eo.com.
Visit www.burle.com for more information or call 1-800-648-1800
— 1-508-347-4000.
top
BURLE
Industries to Introduce New Photosensor Modules at Pittcon 2004.
LANCASTER,
PA – March 15, 2004 – BURLE INDUSTRIES, INC. announces
the introduction of its’ new Photosensor Module line designed
for a wide variety of applications including florescence spectroscopy
in molecular biology, semiconductor wafer inspection and a wide
range of low light measurement detection activities.
The new Photosensor
Module line currently consists of 1 1/8” diameter end window
type modules. Each integrated module packages a high-voltage power
supply, voltage divider and signal amplifier within a sleek and
durable housing. Its unique design incorporates a new active transistor
divider for low part count and excellent linear response. Importantly,
each module offers low power consumption (10mA @ 12V) and minimal
high voltage supply interference.
BURLE Industries’
initial offering of its analog Photosensor Modules consist of
nine distinct modules operating in the 300 to 660 nm and 300 to
880 nm wavelength range in a variety of signal bandwidths to meet
most application requirements. The models are as follows:
Part
Number |
Wavelength
Range |
Signal
Bandwidth |
Physical
Size |
|
300
to 660 nm |
DC
to 20 kHz |
1
3/8 by 6 7/16 inch |
|
300
to 660 nm |
DC
to 200 kHz |
1
3/8 by 6 7/16 inch |
|
300
to 660 nm |
DC
to 10 MHz |
1
3/8 by 6 7/16 inch |
|
300
to 880 nm |
DC
to 20 kHz |
1
3/8 by 6 7/16 inch |
|
300
to 880 nm |
DC
to 200 kHz |
1
3/8 by 6 7/16 inch |
|
300
to 880 nm |
DC
to 10 MHz |
1
3/8 by 6 7/16 inch |
83114
570 |
300
to 660 nm |
DC
to 20 kHz |
1
3/8 by 4 5/8 inch |
83114
571 |
300
to 660 nm |
DC to 200 kHz |
1
3/8 by 4 5/8 inch |
83114
572 |
300
to 660 nm |
DC
to 10 MHz |
1
3/8 by 4 5/8 inch |
Contact BURLE
for additional Photosensor Module specifications and pricing by
calling 1-800-366-2875,
1-717-295-6888 (U.S. calls) or 1-717-295-6773 (Intl. Calls) OR
visit www.burle.com.
For more information about BURLE INDUSTRIES, INC. contact Mr.
J. Luis Vera, BURLE INDUSTRIES, INC. 1000 New Holland Avenue,
Lancaster, PA 17601-5688 USA; 717-295-6888, International Calls:
717-295-6773, Fax: 717-295-6096, e-mail: burlesls@burle.com
top